home company news products solution service & support careers
MTT series (3/3) UPS

点击浏览下一页

Brief introduction

MTT series is three phase in and out online UPS, mainly for the IT device, date center, precision Instrument,bank ,Intelligent equipment, Securities  electric factory ,traffic, industry and so on.

Main features

Pure sine wave output,true online double conversion
Wide input voltage range
Can be set to ECO mode
With EPO function
Can be with 100% unbalance load
Adopt the fourth layer PCB,and SMD technology
Sixth generation IGBT, much higher efficiency, lowe temperaturer, more reliable
Full protection, overload, over voltage, short circuit, over temperature etc
Cold start
Generator compatible
With RS232 and RS485 standard collocate,
Option SMMP and dry contact connection
Option battery manage function

 

Model

MTT-10K

MTT-15K

MTT-20K

MTT-30K

MTT-40K

MTT-60K

Nominal capacity KVA

10KVA

15KVA

20KVA

30KVA

40KVA

60KVA

Work principle

Pure sine wave  on line

Phase

3phase+N+G

Input power factor

>0.87 (option >0.92)

Rectifier

Nominal input voltage

380VAC ,400VAC, 415VAC(option 208VAC,220VAC)

Range

+/-25%

Nominal input frequency

50Hz+/-10%  or   60Hz+/-10%

Output ripple

Less than 2%

Soft start

0-100%  5sec

Charge

Charge mode

constant current to constant voltage, with temp compensation; with Auto change

Float Voltage

432VDC

Boost Voltage

445VDC

Temperature compensation voltage

3mV/ 1 pcs

Charge current

0.1C automatically change follow the batteries

Charge frequency

20% of  Rated capacity

Battery

Battery Type

maintenance-free lead acid battery

Battery capacity

7--999AH settable (according to the capacity)

Battery number

32pcs 12V or  192pcs 2VNominal voltage 384VDC

Inverter  

Phase

Three phase+N

Capacity

Rated capacity *0.8

Nominal  voltage

380VAC, 230/400VAC,240/415VAC(option 208VAC,220VAC)

Output voltage stability

+/-1%( Stable  load); +/-3%( fluctuant load)

Output frequency stability

50Hz/60Hz+/-0. 5%

Creast factor

> 31

Output waveform distortion

Sine wave ,linear load<1%;non-linear load<5%

Dynamic characteristics

 Instant voltage<+/-5%(from 0 to100% ), Instant recover time<10mS

Unbalanced load voltage

+/-5%

Overload Protection

125%10 min150%1min200 1s

efficiency

>95%(full load

Bypass

Phase

Three phase +N

Nominal  voltage

380VAC, 230/400VAC,240/415VAC(option 208VAC,220VAC)

Transfer time

<1mS( static switch with 0 transfer time )

Protection

Input protection

Input voltage/frequency over limited ;wrong phase; lack  phase

Output protection

Over current  short circuit ; factor low protection

Battery protection

Over charge ; over-discharge protection

Temperature protection

Ambient  over temperature protection; inverter over temperature protection

Hardware  failure  protection

Assistant power abnormal, breaker cut off ,breaker overload, power components  over current/over voltage etc protection

System Parameters

Working environment

Temp: 040, relative humidity 30%90 %;( a 1% decrease against 100 meters’ rise. Altitude 4000m MAX)

cooling -down method

COMPULSIVE VENTILATION(with temperature control)

Communication Interface

RS232, RS485; optional SNMP card (for internet long distance monitor )

Anti-surge capacity

10/700μS5KV 8/20μS20KA

Protection level

IP21

 Safety Performance

Vin-n  Vout-n 3000Vac, creepage<3.5mA  isolation resistance >3M(500VDC)

Noise dB

48~55

55~60

DimensionW*D*Hmm

430*760*1080

480*96*1200

Weight(Kg)

230

265

310

342

370

430